STEP 5

4 WIRE POWER CORD INSTALLATION

A. Remove the 3 screws from the connector
block.
B. Remove the grounding screw and strap from
the connector block middle location and the
screw connection to the frame of the range.

C. Insert screws through each power cord
terminal ring and into connector block until
screw engages nut. Be certain that the center
wire is connected to the center screw of the
connector block. Tighten screws securely.
D. Attach ground wire to the frame of the range.

WARNING: THE NEUTRAL WIRE OF
SUPPLY CIRCUIT IS CONNECTED TO
THE NEUTRAL TERMINAL LOCATED
IN THE CENTER OF THE CONNECTOR
BLOCK. THE POWER LEADS MUST
BE CONNECTED TO THE OUTSIDE
(BRASS COLORED) TERMINALS. THE
4TH GROUNDING LEAD MUST BE
CONNECTED TO THE FRAME OF THE
RANGE WITH THE GROUNDING SCREW.

(continued next page)

BEFORE

NEUTRAL
TERMINAL

GROUNDING STRAP
(GROUNDING TO RANGE)

STEP 4
3 WIRE POWER CORD INSTALLATION

Remove the 3 wire terminal screws from the
connector block. Insert screws through each
power cord terminal ring and into the connector
block until the screws engage the nuts. Be
certain that the center wire is connected to the
center screw of the connector block. Tighten
screws securely. Do NOT remove ground strap
connection.

WARNING: THE NEUTRAL OR GROUND
WIRE OF THE POWER CORD MUST BE
CONNECTED TO THE NEUTRAL
TERMINAL LOCATED IN THE CENTER OF
THE CONNECTOR BLOCK. THE POWER
LEADS MUST BE CONNECTED TO THE
OUTSIDE (BRASS COLORED) TERMINALS.

AFTER

NEUTRAL
TERMINAL

GROUNDING
TO RANGE

NEUTRAL
TERMINAL

GROUND
STRAP

POWER CORD

CONNECTOR

BLOCK