G1012 18" Bandsaw

Always keep the tapered table pin in place
when operating the bandsaw.

To mount the table to the bandsaw unit:

1.

Locate the trunnion casting from your loose
parts. The mounting bolts are already in the
table saw unit, near the lower blade guides.
Remove these bolts and their washers.

2.

Line up the holes on the trunnion casting
with the roll pins that are in the bandsaw
unit.. Tap the trunnion casting down onto the
bandsaw unit. Secure with the hex bolts and
washers as shown in

Figure 19.

Table

Figure 19. Trunnion casting mounted to

bandsaw unit.

Figure 21. Positive stop location/installation.

Figure 20. Table mounted on trunnion casting.

3.

Using the table slot for access, remove the
table pin and guide the bandsaw table
around the blade so the blade is centered in
the table. Rotate the table 90˚ and carefully
place the table on the trunnions, so that the
threaded studs go through the holes in the
trunnions.

4.

Using the two plastic knobs from your hard-
ware bags, secure the table to the trunnions
as shown in

Figure 20.

6.

Fit the tapered table pin in the opening of the
access slot.

7.

After verifying that the positive stop holds the
table 90˚ to the blade, set the trunnion point-
er to 0˚ on the trunnion gauge.

5.

The Model G1012 includes a positive stop
bolt for quick table adjustments. Locate the

3

8

"-16 x 3" hex bolt from your hardware bag

and thread it into the trunnion casting as
shown in

Figure 21. Use a

3

8

"-16 hex nut

from the hardware bag to lock the bolt in
place.

Trunnion Pointer