G8027 1 HP Dust Collector

Ensure that the entire system is grounded. If
using plastic blast gates to direct air flow, the
grounding wire must be jumped (

Figure 15)

around the blast gate without interruption to the
grounding system.

Figure 15. Ground jumper wire when using

plastic blast gates or elbows and metal duct.

Plastic Blast Gate

Metal Duct

Copper Ground Wire

Figure 16. Flex-hose grounded to machine.

Ground Screw

Flex-Hose

Internal Ground Wire

External Ground Wire

We also recommend wrapping the outside of all
plastic ducts with bare copper wire to ground the
outside of the system against static electrical
build up. Wire connections at Y’s and T’s should
be made with wire nuts.

Attach the bare ground wire to each stationary
woodworking machine and attach the dust col-
lector frame with a ground screw as shown in

Figure 16. Ensure that each machine is continu-
ously grounded to the grounding terminal in your
electric service panel.