Logfile, Logfile tab, Logoff – GE v6 User Manual

Page 195: Low-battery alarm

Advertising
background image

Secure Perfect 6.1.1 User Manual

193

LogFile

Administration Menu
The LogFile option opens the LogFile Form that allows you to select the computer, name your log file,
and navigate to, or enter the path and directory to your LogFile.

LogFile Tab

Reference Topic:

Diagnostic Settings Form

LogFile Form
Click Add to create a new logfile record or Search to display a list box of previously created LogFiles.
Computer

This field will be unavailable when creating a new
record. The name of your computer will display in this
field.

LogFile

Name or identify your file.

You must enter an

.spl

extension. Example:

COM1log.spl

Path

Designate the path and directory in which to place
your LogFile.

Browse

Click to display a Browse for Folder window, allowing
you to navigate to the directory in which to place your
LogFile.

Save. Now, open the Diagnostic Settings Form from the Administration menu. You will want to select this
LogFile name from the list of files displayed, and assign components for monitoring.

Logoff

File Menu Item
Refer to

Log On/Log Off or Shut Down

.

Low-Battery Alarm

Micro/PX-2000 ONLY: When you create and save a Micro/PX-2000 record, Secure Perfect creates and
supports 11 DI points; however, the 11

th

DI is a low-battery alarm. To configure the 11

th

DI to function as

a low-battery alarm, refer to

DI Board Records Creation

. If power is off and the backup battery is running

low, the micro sends an alarm transaction to the Alarm Monitor form. The alarm displays until the battery
is reset by recharging or the micro is powered back on.