Micro configuration tab – GE v6 User Manual

Page 200

Advertising
background image

Secure Perfect 6.1.1 User Manual

198

Micro Configuration Tab

Reference Topics:

Micro/5-PX or Micro/PX-2000 Records Generation

Reader Board Records Generation

DO Board Records Generation

DI Board Records Generation


Micro Form
Use this tab to assign the appropriate boards to this micro.

Before continuing, verify that the micro type (Micro/5-PX, Micro/5-PXN, Micro/PX-2000, or Micro/PXN-

2000) is correct. The boards listed in the Boards column depend on the type of micro you have selected.

Boards
Lists all boards supported by Secure Perfect and the micro type you have selected. To add a board to the
current micro record, click and drag to the Configuration column. If the addition of the board violates a
micro configuration rule, you will get an error and the board will not be added.
Configuration
Lists the current configuration of the micro. A Power/Comm board is automatically added when you
create the micro record. The reader, digital input, and digital output boards will need to be added to
match the physical setup of the micro.

Following the addition or deletion of a board, you MUST click Save for the appropriate records to be

generated or deleted.

Once you add a board, you are restricted to that type of board only. For example, if you add one 2RP
board, any additional boards MUST be 2RP boards. Likewise, you cannot violate any micro configuration
rule. These are based on the capacities for each micro. For example, for the Micro/5-PX, you can only
add up to four 2RP boards, four 2SRP boards, two 4CRP boards, two 8RP boards, or two CK8RP
boards.

Advertising