Ignitor – GE DPGT750EC/GC User Manual

Page 33

Advertising
background image

– 33 –

6. Slide the gas valve assembly out through the

front of the dryer cavity.

7. Remove the 3 Phillips head screws that

secure the gas valve to the mounting
assembly. Remove the gas valve.

Ignitor

The ignitor is located at the end of the gas valve
assembly in the combustion chamber opening.
Resistance across the ignitor is approximately
300 to 500

Ω.

Screw

Ignitor

Combustion Chamber

Gas Valve Assembly

To remove the ignitor:

1. Shut off the gas and electricity to the dryer.

2. Remove the

Top Cover

,

Front Panel

, and

Drum

.

3. Using a short Phillips screwdriver, remove the

screw that holds the ignitor to the assembly.
Remove the ignitor.

Note: There is a cutout on the edge of the
combustion chamber to allow access to the
screw.

The control operates the gas valves by
supplying voltage based on varying duty
cycles.

It is difficult to determine specific voltages at
the valve due to software algorithms based on
clothes load and temperature settings. The
most accurate diagnostic check is to measure
resistance of the solenoid coils.

To remove the gas valve:

1. Shut off the gas and electricity to the dryer.

2. Remove the

Top Cover

, and

Front Panel

.

3. Disconnect all wiring to the gas valve and

ignitor.

4. Remove the 2 Phillips head screws that hold

the gas valve to the elbow coupling.

5. Remove the 2 Phillips screws that hold the

gas valve assembly to the dryer base.

Elbow Coupling

Dryer Floor

Advertising