PROBLEM

ERROR DISPLAYED FOR CUSTOMER

ERROR DISPLAYED IN SERVICE MODE

POSSIBLE CAUSE(S)

POSSIBLE REPAIR REQUIRED

Blower not

speeding up

No error displayed. Dryer will operate

using Air Dry for all cycles.

Screen will display

"The blower is not

getting up to speed. Please check the

blower motor and inverter and replace if

necessary"

During initial warm-up, the

blower failed to reach the

minimum speed necessary to

turn on the heater.

1.) Wiring connections

or

2.) Blower motor

or

3.) Inverter board

Blocked

Airflow

Screen will display

"Notice A problem

has been detected with this unit"

The

dryer will stop operation.

Screen will display

"There appears to be

an excessive blockage or restriction in

the airflow system. Please check the

blower, ventilation system and lint

filter."

The blower speed is detected

to be at or above 3000 RPM

for over 30 seconds.

1.) Lint filter

or

2.) Vent ductwork

Flame

Detector /

Ignitor

(gas only)

Screen will display

"Notice A problem

has been detected with this unit"

The

dryer will stop operation.

Screen will display

"The ignition system is

not firing. Please check the ignitor,

flame detector, valves and inverter.

Replace if necessary."

Using the feedback signal

from the flame detector, the

control has detected the flame

detector or ignitor is not

working properly.

1.) Wiring connections

or

2.) Flame detector or ignitor

or

3.) Gas valve

or

4.) Inverter

Model

Connector

Failed

Screen will display

"Notice A problem

has been detected with this unit"

The

dryer will stop operation.

Screen will display

"Please check model

connector. It may be missing or the

wrong one may be installed."

The control determined the

model connector plug is

missing on a gas dryer or a

connector was installed on an

electric model.

1.) Model connector plug

or

2.) Wiring connections

Gas Setup

Failed

Screen will display

"Notice A problem

has been detected with this unit"

The

dryer will stop operation.

Screen will display

"The incorrect gas is

being used. Please check the gas orifice

and the model connector."

The control determined the

heat level output does not

match the model connector

plug installed.

1.) Model connector plug

or

2.) Gas orifice type

or

3.) Gas supply