Coolant System

FIRE HAZARD! DO NOT

cut magnesium when

using oil-water solutions

as a cutting fluid! Always

use a cutting fluid intend-

ed for magnesium. The

water in the solution will

cause a magnesium-chip

fire.

This bandsaw has a built-in coolant system that
extends the life of your bandsaw blades by lower-
ing the temperature of the blade and workpiece
when cutting.

See

Cutting Fluid on Page 26 for additional

information.

To use the coolant system:

1. Access the reservoir by removing the rear

panel on the base (see

Figure 23).

Figure 23. Coolant system reservoir and cover.

Figure 24. Coolant control valve.

Coolant Control Valve

NOTICE

Keep the tray chip screen clear so coolant

can recycle to the pump reservoir. NEVER

operate the pump with the reservoir below

the low mark or you will overheat the pump

and void your warranty!

2. Thoroughly clean and remove any foreign

material that may have fallen inside the res-
ervoir during shipping.

3. Fill the reservoir with your chosen cutting fluid

solution and replace the rear panel.

4. Make sure the coolant control valve is turned

OFF.

5. Turn the coolant pump switch ON before

making your cut.

6. Adjust the valve on the coolant hose to con-

trol the flow of coolant (see

Figure 24). Make

sure that the pressure is not so high that cool-
ant spills on the floor and creates a slipping
hazard.

7. When the bandsaw reaches the bottom of the

cut, the motor and coolant system will shut

OFF.