Grizzly G0601 User Manual

Page 15

Advertising
background image

Model g0442/g0601 (Mfg since 3/12)

-13-

g0601 440v conversion

the Model g0601 can be converted for 440v
operation. this conversion job consists of dis-
connecting the machine from the power source,
replacing the control box assembly and the motor
cord, and rewiring the motor for 440v operation.

the necessary conversion kit (part p0601003-1v2)
for this procedure can be purchased by calling
grizzly Customer service at (800) 523-4777.

All wiring changes must be inspected by a quali-
fied electrician before the machine is connected
to the power source. if you need help at any time
during this procedure, call grizzly tech support at
(570) 546-9663.

to rewire the model g0601 for 440v opera-
tion:

1. disConneCt MAChine FroM poWer!

2. record the wire colors and connections of

the four incoming power wires and the four
outgoing motor wires inside the 220v control
box, as illustrated in

figure 3. you can also

refer to the

g0601 Wiring diagram on page

51 for a more complete wiring illustration.

A1

Ground

2T1

6T3

14NO

4T2

1L1

5L3

13NO

3L2

NHD C-18D

2T1

4T2

6T3

98

97

A2

96

O

R

95

21

22

23

25

NTH-25

A2

figure 3. power and motor wire connections (all

other connections hidden for clarity).

4 incoming

power Wires

4 outgoing

Motor Wires

3. disconnect these eight wires, then replace

the 220v control box with the 440v control
box.

4. replace the old motor cord with the new, and

reconnect the wires as recorded in

step 2.

5. remove the old motor cord from the motor.

6. rewire the motor as shown inside the motor

junction cover and attach the new motor
cord.

note: The reference wiring diagram on

Page 51 was current at the time of printing,
but always use the wiring diagram provided
inside the motor junction box, as it will reflect
any changes to the motor shipped with the
machine.

Advertising
This manual is related to the following products: