test run

When the assembly is complete, test run the dust
collection system to make sure it operates prop-
erly.

if, during the test run, you cannot easily locate
the source of an unusual noise or vibration, stop
using the machine immediately, then review the

troubleshooting on page 47.

if you still cannot remedy a problem, contact our
tech support at (570) 546-9663 for assistance.

to test run the dust collection system:

1. Make sure you have read the safety instruc-

tions at the beginning of the manual and that
the machine is set up properly.

2. Make sure all tools and objects used during

setup are cleared away from the machine.

3. review the circuit requirements section

beginning on

page 11 and connect the

machine to the power source.

4. Flip the main power switch at the lower left

hand corner of the control box to the on ("l")
position to enable power to the switch.

5. press the on/oFF button to turn the machine

ON. Make sure your hand stays poised over
the switch in case you need to quickly turn
the machine

OFF.

6. Listen and watch for abnormal noises or

actions. the machine should run smoothly
with little or no vibration or rubbing noises.

— if you suspect any problems, immedi-

ately turn the machine

OFF, then discon-

nect the machine from power. refer to

troubleshooting on page 47 to identify
and fix any problems.

—if you cannot solve the problem with the

use of the

troubleshooting guide, contact

our tech support at (570) 546-9663 for
assistance.

7. press the tiMer button on the control box

and cycle through each of the times to make
sure the indicators light.

8. press the tiMer button on the remote con-

trol and cycle through the times in the same
manner as

step 7.

9. toggle the on/oFF button on both the con-

trol box and the remote control to make sure
they are working properly.

for model g0601 only

the Model g0601 uses a 3-phase motor. For
proper operation, the impeller inside the blow-
er housing must rotate counterclockwise when
viewed from above. since the motor and impeller
are directly connected, you must verify that the
motor rotates in the correct direction.

10. use a ladder to safely observe the motor fan

through the top motor cover as another per-
son turns the machine

ON and OFF.

— if the motor fan rotates counterclockwise

when viewed from above, the rotation
direction is correct.

— if the motor fan rotates clockwise when

viewed from above, the rotation direction
is incorrect and the motor is wired out-of-
phase. perform the

correcting phase

polarity procedure on page 14 to correctly
wire the machine to the power source so
that the motor and impeller spin counter-
clockwise
when viewed from above.

if any part of your body contacts the spin-

ning impeller, severe cutting or amputation

injuries will occur. always keep yourself

and tools away from the impeller when the

machine is connected to power.