12 5.2 jumpers setting – GE AV-300i User Manual

Page 12

Advertising
background image

12

5.2 JUMPERS setting

Encoder/Jumpers setting

S11

S12

S13

S14

S15

S16

S17

S18

S19

S20

S21

S22

S23

DE

OFF

OFF

OFF

OFF

OFF

OFF

ON(*)

-

-

-

-

-

-

SE

ON

ON

ON

ON

ON

ON

-

-

-

-

-

B

B

SESC

ON

ON

ON

ON

ON

ON

-

A

A

A

A

A

A

DEHS

OFF

OFF

OFF

OFF

OFF

OFF

ON(*)

B

B

B

B

B

B

ai3150

-

DE: 5V digital incremental encoder with A /A, B / B, C / C

-

SE: 5V sinusoidal incremental encoder with A /A, B / B, C / C

-

DEHS: 5V digital incremental encoder with A /A, B / B, C / C and three Hall sensor digital position signals (for AC
Brushless motors)

-

SESC: 5V sinusoidal incremental encoder with A /A, B / B, C / C and and two sin/cos traces for absolute position
(for AC Brushless motors or positioning)

(*) If the encoder is not provided with the zero channel, S17=OFF

List of jumpers and dip-switch

Designation

F unction

F actory setting

S0

The setting must not be changed

OFF

S1

The setting must not be changed

OFF

S5-S6

Terminating resistor for the serial interface RS485

ON

ON=Termination resistor IN
OFF=Noterminationresistor

S8

Adaptation of the input signal of analog input 1 (terminals 1 and 2)

OFF

ON=0...20mA/4...20mA
OFF=0...10V/-10...+10V

S9

Adaptation of the input signal of analog input 2 (terminals 3 and 4)

OFF

ON=0...20mA/4...20mA
OFF=0...10V/-10...+10V

S10

Adaptation of the input signal of analog input 3 (terminals 5 and 6)

OFF

ON=0...20mA/4...20mA
OFF=0...10V/-10...+10V

S11-S12-S13

Encodersetting

OFF

S14-S15-S16

ON= Sinusoidal SE or SESC encoder (see above)
OFF=Digital DE or DEHS encoder (see above)

S17

Monitoring of the C-channel of the digital encoder

OFF

ON=C-Channel monitored
OFF=C-Channel not monitored (required for single-ended channels)

S18-S19

Encodersetting

B

S20-S21

Pos.A=digital DEHS encoder (see above)
Pos.B=sinusoidalSESCencoder (see above)

S22-S23

Analog input 3 enabling (alternative with SESC encoder)

A

Pos.A=enabled
Pos.B=disabled

S24

Jumper to disconnect 0V (of 24V) from ground

ON

ON=0V connected to ground
OFF=0V disconnected from ground

S25

Jumper to disconnect 0V (regulation section) from ground

ON

ON=0V connected to ground
OFF=0V disconnected from ground

ai4060