23

with the furnace must be replaced, it must be replaced with wiring
material having a temperature rating of at least 105°C. Any re-
placement wiring must be copper conductor.

115 V

OLT

L

INE

C

ONNECTIONS

Before proceeding with electrical connections, ensure that the sup-
ply voltage, frequency, and phase correspond to that specified on
the unit rating plate. Power supply to the furnace must be N.E.C.
Class 1, and must comply with all applicable codes. The furnace
must be electrically grounded in accordance with local codes or, in
their absence, with the latest edition of The National Electric Code,
ANSI NFPA 70 and/or The Canadian Electric Code CSA C22.1.
Use a separate fused branch electrical circuit containing properly
sized wire, and fuse or circuit breaker. The fuse or circuit breaker
must be sized in accordance with the maximum overcurrent pro-
tection specified on the unit rating plate. An electrical disconnect
must be provided at the furnace location.

NOTE: Line polarity must be observed when making field
connections.

I

N

UPRIGHT

UPFLOW

INSTALLATIONS

,

THE

DRAIN

TRAP

MUST

BE

MOUNTED

ON

THE

OPPOSITE

SIDE

OF

THE

UNIT

FROM

THE

JUNCTION

BOX

. T

HIS

WILL

REDUCE

THE

RISK

OF

WATER

REACHING

THE

JUNCTION

BOX

IN

THE

EVENT

OF

A

BLOCKED

DRAIN

CONDITION

.

WARNING

Connect hot, neutral, and ground wires as shown in the wiring
diagram located on the unit’s blower door. For direct vent applica-
tions, the cabinet opening to the junction box must be sealed air
tight using either a UL approved bushing such as Heyco Liquid
Tight or by applying a UL approved non-reactive sealant to bush-
ing.
Line polarity must be observed when making field connections.
Line voltage connections can be made through either the right or
left side panel. The furnace is shipped configured for a left side
electrical connection with the junction box located inside the burner
compartment. To make electrical connections through the oppo-
site side of the furnace, the junction box must be relocated to the
other side of the burner compartment prior to making electrical
connections. To relocate the junction box, follow the steps shown
below.

NOTE: Wire routing must not to interfere with circulator blower
operation, filter removal, or routine maintenance.

E

DGES

OF

SHEET

METAL

HOLES

MAY

BE

SHARP

. U

SE

GLOVES

AS

A

PRECAUTION

WHEN

REMOVING

HOLE

PLUGS

.

WARNING

1. Remove the burner compartment door.
2. Remove and save the two screws securing the junction box

to the side panel.

3. Relocate junction box and associated plugs and grommets

to opposite side panel. Secure with screws removed in
step 2.

*

*

*

*

*

*

*

*

*

STANDARD

JUNCTION BOX

LOCATION

ALTERNATE

JUNCTION BOX

LOCATION

Junction Box Relocation

HIGH VOLTAGE!
T

O

AVOID

THE

RISK

OF

INJURY

,

ELECTRICAL

SHOCK

OR

DEATH

,

THE

FURNACE

MUST

BE

ELECTRICALLY

GROUNDED

IN

ACCORDANCE

WITH

LOCAL

CODES

OR

IN

THEIR

ABSENCE

,

WITH

THE

LATEST

EDITION

OF

THE

N

ATIONAL

E

LECTRIC

C

ODE

.

WARNING

To ensure proper unit grounding, the ground wire should run from
the furnace ground screw located inside the furnace junction box
all the way back to the electrical panel. NOTE: Do not use gas
piping as an electrical ground. To confirm proper unit grounding,
turn off the electrical power and perform the following check.

1. Measure resistance between the neutral (white) connection

and one of the burners.

2. Resistance should measure 10 ohms or less.

This furnace is equipped with a blower door interlock switch which
interrupts unit voltage when the blower door is opened for servic-
ing. Do not defeat this switch.

24 V

OLT

T

HERMOSTAT

W

IRING

NOTE: Wire routing must not interfere with circulator blower
operation, filter removal, or routine maintenance.

Low voltage connections can be made through either the right or
left side panel. Thermostat wiring entrance holes are located adja-
cent to the junction box locations in the blower compartment. Wire
routing must not to interfere with circulator blower operation, filter
removal, or routine maintenance. Refer to the following figure for
thermostat connections to the integrated control module terminal
strip.

W

W

W

Y

Y

Y

C

C

R

R

R

G

G

W

Y

C

R

G

HEATING

ROOM

THERMOSTAT

HEATING AND

COOLING ROOM

THERMOSTAT

FURNACE

FURNACE

REMOTE

CONDENSING

UNIT

Thermostat Diagram

This furnace is equipped with a 40 VA transformer to facilitate use
with most cooling equipment. Consult the wiring diagram, located
on the blower compartment door, for further details of 115 Volt and
24 Volt wiring.

XII. GAS SUPPLY AND PIPING

G

ENERAL

The furnace rating plate includes the approved furnace gas input
rating and gas types. The furnace must be equipped to operate on
the type of gas applied. This includes any conversion kits required
for alternate fuels and/or high altitude.