110 vac, Bf c c d – Grizzly G0717 User Manual

Page 19

Advertising
background image

Model g0717 (Mfg. since 9/10)

-17-

11. open the motor junction box, loosen the ter-

minal screws indicated in

figure 14, feed the

cord through the strain relief on the junction
box, then connect the wires as shown.

12. Make sure all wiring connections are secure,

tighten the strain relief on the motor junction
box to prevent the cord from being acciden-
tally pulled out, then replace the motor junc-
tion box cover.

13. remove the two hex bolts shown in figure

15.

14. slide the pulley cover behind the motor pulley

first, then the gearbox pulley. Mount it using
the hardware removed in

step 13, as shown

in

figure 16.

Start

Capacitor

400MFD

125VAC

Run

Capacitor

40MFD

250VAC

Hot

Ground

Hot

Cutting Fluid

Pump Motor

1/8HP, 220V

Control Panel

(viewed from behind)

Main Motor 1-1/2HP, 220V

Saw Travel

Limit Switch

6-15 Plug

(Included)

220

VAC

G

Ground

Start

Capacitor

3MFD

450VAC

Ground

1

2

4

4

1

1

1

1

5

5

3

3
3

3

2

4

4 0

1

2

1

3

2

2

2

2

V1

V1

U1

U1

V2

U2

4

1

3

2

Cutting Fluid
Pump Switch

Emergency Stop Button

Start Button

ON Lamp

b

b

f

c

c

d

Cutting Fluid

Pump Motor

Rewired for 110V

Ground

Start

Capacitor

3MFD

450VAC

V2

U2

4

1

3 2

e

Run

Capacitor

40MFD

250VAC

Main Motor, Rewired for 110V

Ground

4

1
3

2

V1

V1

U1

U1

Rewired for 110V

Rewired for 110V

d

e

Neutral

Hot

Ground

110 VAC

5-20 Plug

(As Recommended

for 110V)

Rewired for 110V

f

figure 14.

Wiring motor.

figure 16.

Mounting belt cover.

loosen these

terminals

strain

relief

figure 15.

Belt cover hardware.

hex Bolts & Washers

hex Bolts &

Washers

Belt

Cover

Advertising