-33-

While simple in concept and function, many
issues must be taken into account to find and use
the correct cutting fluid. always follow all product
warnings and contact the fluid manufacturer for
unanswered questions.

use the information below as a guideline to
choose the appropriate cutting fluid. always refer
to the cutting fluid manufacturer for specific appli-
cation and safety information:

For cutting low alloy, low carbon, and gen-
eral-purpose category metals with a bi-metal
blade —use a water soluble cutting fluid.

For cutting stainless steels, high carbon, and
high alloy metals, brass, copper and mild
steels—use "neat Cutting oil" (commonly
undiluted mineral oils) that have extreme
pressure additives (ep additives).

For cutting cast iron, cutting fluid is not rec-
ommended.

Remember: Too much flow at the cutting fluid
nozzles will make a mess and can make the work
area unsafe; and not enough fluid at the cut will
heat the blade, causing the blade teeth to load up
and break.

tip: Using a refractometer or hydrometer to
replenish water in water-based coolant can extend
the life of blades and coolant, and ensure consis-
tent cutting results.

Cutting fluid

BiOLOGiCaL

anD

pOisOn hazaRD! use

proper personal protection

equipment

when

handling cutting fluid

and follow federal, state,

and fluid manufacturer

requirements to properly

dispose of cutting fluid.

the reservoir on this machine is designed

to store cutting fluid. During storage, some

fluids grow dangerous microbes, or due to

the collection of toxic metal chips in the

fluid, the fluid can become a potent and

extremely poisonous solution to humans

and animals.

usE the correct personal protection

equipment when handling cutting fluids to

prevent infections and poisoning.

usE a good bactericide and fungicide for

additional protection.

fOLLOw federal, state, and the fluid

manufacturer requirements to properly

dispose of cutting fluid when it becomes

unsafe.

BiOLOGiCaL and pOisOn

hazaRD!

NOTICE

Clean coolant system with a bactericide and

fungicide between coolant changes to pre-

vent recontamination.