Clearances, Height requirements, Warning – MartinLogan VENT-FREE FIREPLACE SYSTEMS 33ISDG User Manual

Page 11

Advertising
background image

23D8036

11

33"

15

1

/

4

"

22

3

/

4

"

23

7

/

8

"

B

A

9"

Minimum

9"

Minimum

42"

Minimum

CLEARANCES

AND

HEIGHT REQUIREMENTS

NOTE: Clearances are necessary to combustible
surfaces only. No clearance is necessary for
noncombustible surface.

Sidewall clearances:

The clearance from the inside of

the appliance to any combustible adjacent wall should no
be less than 9." See Figure 5.

Ceiling clearance:

The ceiling must be at least 42" from

the top of the firebox opening. See Figure 5.

Back wall clearance:

The appliance can be placed against

the combustible back wall.

Floor clearance:

The fireplace may not be installed onto

any combustible flooring material, such as carpeting, vinyl or
tile without the hearth or a minimum 22 GA (0.030") metal
or a minimum 1/2" wooden base covering the entire width
and depth of the base.

Mantel clearances:

The canopy supplied with the unit

must be installed. If a combustible mantel is installed. It must
meet the clearance requirements shown in Figure 8.

The dimensions shown in Figures 5 and 8 and defi ned in the fi replace manufacturer's
instructions are minimum clearances
to maintain when installing this heater. Left and
right clearances are determined when facing the front of the heater.

Follow these instructions carefully to ensure safe installation. Failure to follow
instructions exactly can create a fi re hazard.

W

ARNING

Figure 5 - Sidewall and Ceiling Minimum

Clearances

Figure 6 - Dimensions for Installing in

Masonry Fireplace or a UL Listed Box

BEFORE INSTALLING THE FIREPLACE INSERT

Have fireplace floor and chimney professionally cleaned to
remove ashes, soot, creosote or other obstructions. Close and
seal any fresh air vents or ash clean-out doors located on
floor or wall

Accessory Face Plates

A

B

Small

33" 43"

Large

36" 50"