NOTICE: A qualifi ed gas appliance installer must connect the heater to the gas supply. Consult all
local codes.

IMPORTANT: Loosen the pipe adapter on the fl ex tube before installing to the system piping.

Figure 17 - Gas Connection

To Heater

Valve

Stainless

Flexible Tube

CONNECTING THE GAS

Use new black or steel pipe. Internally tinned copper or copper tubing can be used
per National Fuel Code, section 2.6.3, providing gas meets hydrogen sulfi de limits,
and where permitted by local codes. Gas piping system must be sized to provide
minimum inlet pressure (listed on Data Plate) at the maximum fl ow rate (BTU/Hr).
Undue pressure loss will occur if the pipe is too small.

A manual shutoff valve must be installed upstream of the appliance. Union tee
and plugged

1

/

8

" NPT pressure tapping point should be installed upstream of the

appliance. See Figure 17.

CAUTION

Manual Shutoff

Valve

Pipe

Pipe Coupling

Always use an external regulator for all propane/L.P.G. heaters and high pressure one to two-pound systems only, to
reduce the supply tank pressure to a maximum of 13" w.c. This is in addition to the internal regulator in the heater valve.

CHECK GAS TYPE: The gas supply must be the same as stated on the heater's rating
plate. If the gas supply is different, DO NOT INSTALL THE HEATER. Contact your
dealer for the correct mode.

W

ARNING

Locations that Pressure

Tapping Point May Be

Installed

Gas Supply

Inlet