Electrical wiring (milli-volt), Wa rning – MartinLogan VENT-FREE FIREPLACE SYSTEMS 33ISDG User Manual

Page 19

Advertising
background image

23D8036

19

ELECTRICAL WIRING (MILLI-VOLT)

The milli-volt valve is a self-powered combination gas control
THAT DOES NOT REQUIRE 110 VAC TO OPERATE.

Figure 20 - Wiring Diagram

Optional Wall

Switch or Remote

Receiver

Switch

On/Off
Switch

On/Off
Switch

Wall

Switch

ODS

Pilot

Millivolt

Valve

TH = 3

TP = 1

TP/TH = 2

ODS

Pilot

Spade

Terminal

Label all wires prior to disconnection
when servicing controls. Wiring
errors can cause improper and
dangerous operation. Verify proper
operation after servicing.

W

A

RNING

CONNECTING OPTIONAL WALL SWITCH OR THERMOSTAT

1. Use 18 awg, two-wire cable, 15 feet maximum length.
2. At one end of the cable, connect both wires to the wall switch or thermostat. At the other end, connect one wire to TP/TH

and one wire to TH, or connect the wall switch/thermostat to the two male (0.25") terminals on the left side of the unit.
The color of the wires does not matter.

See Figure 20 and installation instructions
provided with optional wall switch, thermo-
stat or remote control for wiring instructions.
A maximum length of 15 feet of 18awg two
conductor wire is to be used for wall switch
or thermostat installations.

Note thermostats and switches must
be suitable for milli-volt operation.