9) sensir input configuration, 10) alarm configuration – MITSUBISHI ELECTRIC DX-VS1 User Manual

Page 28

Advertising
background image

DX-VS1UE User

DX-VS1UE User

DX-VS1UE User

DX-VS1UE User’’’’s Manual

s Manual

s Manual

s Manual

27

9) Sensir Input Configuration

This page is used to set sensor input

status. This is related with E-mail and

FTP function and Alarm preset func-

tion.

(1) Device Type for Input Ports

Administrator defines active state of

4 digital input ports. If you connect

normal open type device to input

port, you should select “NO (Normal

Open).” With normal close type de-

vice, you should select “NC (Normal

Close).”

(2) Current State for Input Ports

DX-VS1UE shows current status of the 4 input ports used for connecting with a sensor device. In

the status panel, active state or Non-active state message appears. “Non Active” state means that

connected device didn’t detect any event when the ‘Apply’ button was clicked. Though this mes-

sage is not updated until you click ‘Apply’ button again, DX-VS1UE keeps receiving status infor-

mation from the connected device.

10) Alarm Configuration

This page is used to set conditions for

image recording in event status, so that

DX-VS1UE sends the images through e-

mail or FTP.

(1) Motion Detection Threshold

Administrator sets threshold for motion

detection function. Threshold ‘0’ is the

most sensitive state and ‘900’ is the

dullest state.

(2) Alarm Parameters for E-mail /

FTP Application

Administrator defines the conditions for

recording image to DX-VS1UE, if DX-

VS1UE detects some event through mo-

tion detection function (MD Event) or external devices (SID1, SID2, SID3, and SID4). DX-VS1UE

can record 2 frames for 2 seconds before the event and 2 frames for 2 seconds after the event as well

as 1 frame at the moment of event. The maximum recording rate is 1 frame per second and the total

frames are maximum 5. DX-VS1UE records the images and send them through e-mail or FTP ac-

Advertising