8 SPECIFICATIONS

GENERAL SPECIFICATIONS

Modulation

16K0F3E, 11K0F3E , 8K0D1E, 8K0F1E

Data Rate

P25 : 9.6 kb/s

Symbol Rate

P25 : 4.8 kb/s

Protocol

Project 25-CAI : 4.4 kb/s IMBE

Encryption Algorithms

DES-OFB, AES

Channel Capacity

999

Operating Voltage Range

13.6 Vdc

± % 20 (10.88-16.32 Vdc)

Standby Current Drain (backlight off)

≤ 0.4 A

RX Current Drain

≤ 1.5

TX Current Drain

≤ 8.5 A

Display

64x128 pixel LCD

Keypad

20 key, back lit

Dimensions (HxWxL) (projections not included)

1.8x6.5x6.5 in (46x165x165 mm)

Weight

1.50 kg


ENVIROMENTAL SPECIFICATIONS

Operating Temperature Range

-30

°C / +60°C

Storage Temperature Range

-40

°C / +85°C

Humidity

% 95, 50

°C

ESD

IEC 801- 2KV

Water and Dust Protection

IP65, MIL-STD