14D2099

Measure
this
distance

Heater in
Fireplace or
Firebox

Heat
Resistant
Material

CLEARANCES and HEIGHT REQUIREMENTS

Heat resistant material (minimum requirements) with no wooden mantel or other combustible projection:

To install the gas logs into a fireplace with no wooden mantel, shelf or other combustible projection above the fireplace
opening, measure the heat resistant material height, per Figure 4, then refer to TABLE A.

Heat resistant materials such as slate and marble must be at least 1/2" thick. Sheet metal should not be installed onto
combustible material.

IMPORTANT:

If you cannot meet these minimum clearances you must operate the heater with chimney flue damper open.

Refer to “INSTALLING VENTED APPLICATIONS” found on page 17.

Figure 5 - Measuring Heat Resistant Material

HEAT RESISTANT

REQUIREMENTS FOR SAFE INSTALLATION

MATERIAL

MEASUREMENT

DLX18/GLX18

DLX/GLX 24 AND 28

All Models

All Models

12" or more

Hood not required.

Hood not required.

8" to less than 12"

Hood not required.

Extend heat resistent material to 12"
or install hood.

See Figure 5.

Less than 8"

Extend heat resistant

Extend heat resistant material to at

material to at least 8"

least 8" and install hood.

See Figure

5. OR, extend heat resistant material
to a height of at least 12".

TABLE A - Heat Resistant Material Requirements with no Mantel or Combustible Projection