Ca ution, Connecting the gas – Monessen Hearth DLX28 User Manual

Page 19

Advertising
background image

14D2099

19

Pipe Coupling

To Heater

Valve

CA

UTION

Use new black iron or steel pipe. Internally tinned copper or copper tubing can be
used per National Fuel Code, section 2.6.3, providing gas meets hydrogen sulfide
limits, and where permitted by local codes. Gas piping system must be sized to
provide minimum inlet pressure (Listed on Data Plate) at the maximum flow rate
(BTU/Hr). Undue pressure loss will occur if the pipe is too small.

A manual shutoff valve must be installed upstream of the appliance. Union tee and
plugged

1

/

8

" NPT pressure tapping point should be installed upstream of the

appliance.

Refer to Figure 15.

CONNECTING THE GAS

NOTICE: A qualified gas appliance installer must connect the heater to the gas supply. Consult all local
codes.

IMPORTANT:

Hold heater valve firmly with a wrench to prevent movement when connecting to inlet pipe.

Manual Shutoff

Valve

Pipe

Stainless

Flexible Tube

Figure 15 - Gas Connection

Always use an external regulator for all propane/LPG heaters only, to reduce the supply tank pressure to a maximum of
13" w.c. This is in addition to the internal regulator in the heater valve.

CA

UTION

CHECK GAS TYPE: The gas supply must be the same as stated on the heater’s
rating plate. If the gas supply is different, DO NOT INSTALL THE HEATER. Contact
your dealer for the correct model.

Gas Supply Inlet

Locations that the

Pressure Tapping

Point May Be

Installed

Advertising