Product features, Specifications – Monessen Hearth DLX28 User Manual

Page 6

Advertising
background image

6

14D2099

PROPANE / LPG

Note: An external regulator is required to reduce supply pressure to a maximum of 13" w. c.

MANUAL / T-STAT PRESSURE

MILLIVOLT PRESSURE

Regulator Pressure Setting:

10" w.c.

Regulator Pressure Setting:

10" w.c.

Gas Inlet Pressure:

Maximum 13" w.c.

Gas Inlet Pressure:

Maximum 13" w.c.

Minimum 11" w.c.

Minimum 11" w.c.

NATURAL GAS

MANUAL / T-STAT PRESSURE

MILLIVOLT PRESSURE

Regulator Pressure Setting:

3" w.c.

Regulator Pressure Setting:

3.5" w.c.

Pilot Regulator:

3.5" w.c.

Gas Inlet Pressure:

Maximum 10

1

/

2

" w. c.

Gas Inlet Pressure:

Max. 10

1

/

2

" w. c.

Minimum 5" w.c.

Min. 5" w.c.

IGNITION CONTROLS

Piezo ignitor allows ignition of the pilot without the use of matches or batteries.

Manual control has four (4) positions:

OFF

-

All gas to the gas logs is shut off at the valve.

IGN

-

Valve position to light/maintain a standing pilot.

LOW

-

Minimum gas rate — front burner provides a realistic glow on the center log.

HI

-

Maximum gas rate — front burner provides a realistic glow on the center log, plus the rear burner
provides a pleasing yellow flame.

Gas Rate

Model Number

Control

Max BTU/Hr

Min BTU/Hr

DLX18NV, GLX18NV

Manual

26,000

16,000

DLX24/28NM, GLX24/28NM

Manual

32,000

19,000

DLX18NT, GLX18NT

T-Stat

26,000

16,000

DLX24/28NT

Milli-Volt

26,000

20,000

DLX18NV, GLX18NV

Milli-Volt

26,000

17,000

DLX24/28NV, GLX24/28NV

Milli-Volt

32,000

22,000

Gas Rate

Model Number

Control

Max BTU/Hr

Min BTU/Hr

DLX18PV, GLX18PV

Manual

22,000

14,000

DLX24/28PM, GLX24/28PM

Manual

33,000

19,000

DLX18PT, GLX18PT

T-Stat

26,000

16,000

DLX24/28PT

Milli-Volt

28,000

20,000

DLX18PV, GLX18PV

Milli-Volt

22,000

17,000

DLX24/28PV, GLX24/28PV

Milli-Volt

33,000

22,000

PRODUCT FEATURES