Clearances, Height requirements – Monessen Hearth DLX28 User Manual

Page 15

Advertising
background image

14D2099

15

Heater in
Fireplace or
Firebox

Heat
Resistant
Material

10" and Less

12" 28"

Minimum of 8"
Heat
Resistant
Material

Mantel

Hood

2

1

/

2

"

8"

6"

7"

14

1

/

2

"

4"

Figure 10 is an example of an unsafe mantel installa-
tion.
This mantel projects 4" at 8" above the opening,
exceeding the maximum acceptable distance of 2

1

/

2

"

The mantel also projects 7" at 14

1

/

2

" above the open-

ing, exceeding the maximum acceptable distance of 6".

If your mantel profile is unsafe, you may either:

• Raise the mantel to an acceptable height

OR

• Remove the mantel

CLEARANCES

AND

HEIGHT REQUIREMENTS

Figure 9 - Minimum Mantel Clearance with No Hood — DLX/GLX 24 and 28

Figure 10 - Unacceptable Mantel Clearance

Example:

The bottom of the mantel may project from the wall a
maximum of 10" at a minimum of 28" above the opening.