Caution, Electrical wiring (milli-volt) – Monessen Hearth DLX28 User Manual

Page 21

Advertising
background image

14D2099

21

CAUTION

Label all wires prior

to disconnection

when servicing

controls. Wiring

errors can cause

improper and

dangerous

operation. Verify

proper operation

after servicing.

ELECTRICAL WIRING (MILLI-VOLT)

The milli-volt valve is a self-powered combination gas control

THAT DOES NOT USE 110 VAC TO OPERATE.

CONNECTING OPTIONAL WALL SWITCH OR THERMOSTAT

1. Use 18 awg, two-wire cable, 20 feet maximum length.

2. At one end of the cable, connect both wires to the wall switch or thermostat. At the other end, connect one wire to

TP/TH and one wire to TH. The color of the wires does not matter.

Switch

On/Off
Switch

On/Off
Switch

Wall

Switch

ODS

Pilot

Millivolt

Valve

Red

TH = 3

TP = 1

TP/TH = 2

Figure 19 - Wiring Diagram

Red

ODS

Pilot

Spade

Terminal