SECTION 4 − SPECIFICATIONS

4-1. Weld, Power, And Engine Specifications

Welding

Mode

Rated

Welding

Output

Maximum

Open-Circuit

Voltage

Amperage

Range In

CC Mode

Voltage

Range In

CV Mode

Generator

Power Rating

Fuel Capacity

Engine

CC/DC

300 A, 32 V,

60% duty

99

5 − 375 A

10 − 34 V

Single-Phase,

12 kVA/kW

100/50 A

13 gal (49 L)

Kubota DH905

Water-Cooled,

Three-Cylinder

CV/DC

60% duty

Cycle

99

5 − 375 A

10 − 34 V

100/50 A,

120/240 V AC,

60 Hz

13 gal (49 L)

Tank

Three-Cylinder,

Four-Cycle, 26 HP

Diesel Engine