OM-492 Page 44

Trouble

Remedy

Engine does not go to low (idle) speed

with Engine Control switch in Run/Idle

position.

Be sure Engine Control switch S2 is in Run/Idle position.

Remove all weld and generator power loads.

Turn off remote device connected to Remote 14 receptacle RC14 (see Section 5-8).

Check for obstructed movement of throttle solenoid linkage.

Have Factory Authorized Service Agent check voltage regulator board PC8 and current transformer

CT1.

Engine does not go to high (run) speed

when generator power or large weld

load is applied with Engine Control

switch in Run/Idle position.

Place Engine Control switch in the Run position. Have Factory Authorized Service Agent check unit.

Engine uses oil during run-in period;

wetstacking occurs.

Dry engine (see Section 10 and engine manual).

Coolant recovery tank continuously

overflows.

Bleed air from radiator, and replace lost coolant (see Section 5-3).