3. meter functions, 4. mode switch settings, Sections 6-3 – Miller Electric PipePro 304 User Manual

Page 30: Tion 6-4

Advertising
background image

OM-492 Page 26

6-3. Meter Functions

.

The meters display the actual weld output values for approximately three seconds after the arc is broken.

Mode

Meter Reading At Idle

Meter Reading While Welding

Scratch

Start TIG

V

A

Actual Volts (OCV)

Preset Amps

80.0

85

Actual Volts

Actual Amps

V

A

10.3

85

Lift-Arc TIG

Actual Volts

Preset Amps

V

A

7.0

85

Actual Volts

Actual Amps

V

A

10.3

85

TIG

Blank

Preset Amps

V

A

85

Actual Volts

Actual Amps

V

A

10.3

85

MIG

Preset Volts

Blank

V

A

24.5

Actual Volts

Actual Amps

V

A

24.5

250

Pulsed

MIG

Pulse Display

Pulse Display

V

A

PPP

PPP

Actual Volts

Actual Amps

V

A

24.5

250

CC

Blank

Preset Amps

V

A

85

Actual Volts

Actual Amps

V

A

24.5

85

Stick

Actual Volts (OCV)

Preset Amps

V

A

80.0

85

Actual Volts

Actual Amps

V

A

24.5

85

V-Sense

Feeder

Flashes OCV And Preset

Blank

V

A

80.0

Actual Volts

Actual Amps

V

A

24.5

250

6-4. Mode Switch Settings

.

The Stick and CC modes provide the Adaptive Hot Start

feature, which automatically increases the output amperage at the start of a weld should

the start require it. This eliminates electrode sticking at arc start.

Mode Switch Setting

Process

Output On/Off Control

Mode Switch Setting

Process

Output On/Off Control

Scratch Start TIG

GTAW

Electrode Hot

Lift-Arc TIG

GTAW − See Section 6-5

Electrode Hot

TIG

GTAW With HF Unit, Pulsing Device, Or Remote Control

At Remote 14

MIG

GMAW

At Remote 14

Pulsed MIG

GMAW-P (Requires an external pulsing device.)

At Remote 14

CC

Stick (SMAW) With Remote On/Off

At Remote 14

Stick

SMAW

Electrode Hot

V-Sense Feeder

MIG (GMAW) With Voltage Sensing Wire Feeder

Electrode Hot

Advertising