7-2. Optional GFCI Receptacles And Circuit Breakers

Ref. ST-207 554-A

!

If unit does not have GFCI

receptacles, use GFCI-pro-

tected extension cord.

.

Generator power decreases as
weld current increases.

1

120 V 20 A AC GFCI Duplex

Receptacle GFCI-2

2

120 V 20 A AC GFCI Duplex

Receptacle GFCI-3

GFCI-2 and GFCI-3 supply 60 Hz

single-phase power at weld/power

speed. Maximum output from

GFCI-2 or GFCI-3 is 2.4 kVA/kW.

Circuit protection is the same as

standard receptacles.
If a ground fault is detected, the GFCI

Reset button pops out and the circuit

opens to disconnect the faulty equip-

ment. Check for damaged tools,

cords, plugs, etc. connected to the

receptacle. Press button to reset re-

ceptacle and resume operation.

.

At least once a month, run en-
gine at weld/power speed and

press Test button to verify GFCI

is working properly.

1

2

7-3. Wiring Instructions For Optional 240 Volt, 3-Phase Twistlock Plug (NEMA L15-30P)

Plug2 7/99 − 802 437

1

240 V AC Three-Phase, 30 A,

3P4W Twistlock Plug

2

Load 1 (Brass) Terminal (X)

3

Load 2 (Brass)Terminal (Y)

4

Load 3 (Brass) Terminal (Z)

5

Ground (Green) Terminal (G)

6

Cord Grip

Strip cord jacket back enough to sep-

arate conductors.
Strip conductors enough to make

good contact with plug terminals.

Make plug connections and reinstall

cord grip.
Tighten cord grip assembly screws.

Do not overtighten.

1

2

240V

240V

240V

Tools Needed:

6

3

4

5