OM-492 Page 22

5-9. Guidelines For Installing Customer-Supplied Emergency Air Shutdown Valve

A customer-supplied emergency air shutdown

valve can be installed to stop the engine imme-

diately in emergency situations.
These guidelines show the typical installation of

a Gator ESD 175-275-L3 air shutdown valve.

Installation of other air shutdown valves may

differ from that shown. Contact the air shut-

down valve manufacturer or a Factory Autho-

rized Service Agent for additional installation

and operation information.

!

Stop engine, and let cool.

!

Disconnect battery negative (−) cable.

Open doors and remove side panels.
1

Air Cleaner

2

2 in (51 mm) Hose Clamp

3

1-3/4 x 2 in (44 x 51 mm) Rubber Hose

4

Air Shutdown Valve

(Gator ESD 175-275-L3)

5

1-3/4 x 16-1/2 in (44 x 419 mm) Flexible

Radiator Hose (NAPA Part No. FM68)

.

Use thick-walled rubber hose. Do not use
heater hose. (Heater hose could let dirt into

engine.)

6

Engine Air Inlet

7

Shutdown Control

8

42 in (1067 mm) Shutdown Control Cable

(Supplied By Gator)

9

Shutdown Valve Reset Lever

Install components as shown.
Be sure air shutdown valve is installed with air

flow arrow pointing toward air inlet. Use cable

ties to keep air shutdown system components

away from hot or moving parts.
Verify the emergency air shutdown system op-

erates correctly. After testing, use reset lever to

reset air shutdown valve.
Reinstall side panels and close doors.
Reconnect battery negative (−) cable.