Vermont castings resolute acclaim – Majestic Appliances 2490 User Manual

Page 14

Advertising
background image

14

Vermont Castings Resolute Acclaim

2000893

Minimum Wall Shield Requirements for Common Installations

A

B

A = 48” (1220mm)
B = 36” (910mm)

ST602

Fig. 16 A rear-exit stove with reduced rear wall clearance
only.

A

B

C

D

E

A

E

F

A = 26” (660mm)
B = 49” (1230mm)
C = 44” (1120mm)
D = 36” (910mm)
E = 1” (25mm)
F = 23” (580mm)

ST604

Fig. 17 A top-exit stove with 90

°

elbow and no stove or

connector heat shields. Note clearance between chimney
connector and ceiling.

H

H

H

H

D

F

A

B

E

D

C

G

A = 26” (660mm)
B = 23” (580mm)
C = 44” (1120mm)
D = 36” (910mm)
E = 11” (280mm)
F = 43” (1090mm)
G = 47” (1190mm)
H = 1” (25mm)

ST603

Fig. 18 A top exit stove with heat shields on both the stove
and chimney connector. Reduced rear and side wall clear-
ances. The chimney connector heat shield must be exactly
28”. Note that rear and side wall shields meet at corner.

E

C

D

A

B

A = 26” (660mm)
B = 44’ (1120mm)
C = 36” (910mm)
D = 48” (1220mm)
E = 1” (25mm)

ST605

Fig. 19 A top-exit stove with a wall shield only no pipe or
stove heat shields). A 26” wide section of rear wall shield
must be centered behind the connector.

F

F

C

D

A

A

E

C

B

D

B

A = 26” (660mm)
B = 44” (1120mm
C = 36” (910mm)
D = 36” (910mm)
E = 5” (130mm)
F = 1” (25mm)

ST607

Fig. 21 A top-exit stove with reduced rear and side wall
clearance. Wall shields must meet at corner.

G

G

C

E

A

A

D

C

B

F

A = 26” (660mm)
B = 44” (1120mm)
C = 36” (910mm)
D = 11” (280mm)
E = 43” (1090mm)
F = 49” (1230mm)
G = 1” (25mm)

ST606

Fig. 20 A top-exit stove with reduced rear and side wall
clearances. Note that rear wall shield must extend com-
pletely to corner.

Advertising