Vermont Castings Resolute Acclaim

2000893

Repair Air Leaks to Prevent Overheating

and Excessive Fuel Consumption

Adjust the Door Latch

The door gasket will compress after use. To restore a
tight seal, adjust the tension on the latch:

• Remove the Allen head button screw that attaches the
door latch tab to the stove front. (Fig. 34)

• Remove one of the washers that separates the tab
from the front (save it for future use.)

• Replace the remaining washers and the door latch
tab.

•Remove another washer if necessary.

• Test the seal by closing the door on a slip of paper
and attempting to pull the paper free. If the paper is
freed without tearing, the gasket isn’t snug enough at
that spot.

If the paper indicates a low spot in a specific area, try
“adjusting” the gasket in that area. Pack more cement
or a smaller diameter gasket into the channel beneath
the gasket so that the main gasket is raised and makes
contact with the door frame. This procedure should
solve the problem. If it doesn’t, replace the gasket
following these steps:

•Wearing safety goggles and a dust mask, remove the
original gasket by grasping an end and pulling firmly.

•Use a wire brush or the tip of a screwdriver to clean
the channel of any remaining cement or bits of gasket.

• Apply a thin bead of stove cement in the newly-
cleaned groove.

• Pack the gasket into the groove. Wait until you are a
couple inches from the end before you cut it.

Test the gasket by closing the door on a slip of paper
such as described above. Adjust the gasket in any
areas where an inadequate seal is evident.

Adjust the Door

Although it is unlikely that adjusting it will be necessary,
the height of the Resolute Acclaim’s front load door is
adjustable. The lower door hinge pin has a shoulder
that lifts or lowers the door as you screw the pin up or
down.

Repair Missing Cement in Seams

The cement in the stove seams may deteriorate over
time and fall out in places. Just as with the stove
doors, it is necessary to keep the seam seals in good
condition. Spot-fix with furnace cement (available from
your local dealer) any areas where the cement seal is
visibly deteriorated. Allow 24 hours for the new cement
to dry.

Adjust the Damper as Needed

The tension of the Resolute Acclaim’s torsion bar is
adjustable to compensate for compression of the
gasket that seals the damper to the damper frame. To
adjust the damper:

•Loosen the lock nut on the set screw in the center of
the damper. (Fig. 35)

•Turn the set screw approximately one half-turn
clockwise.

•Re-tighten the lock nut and test the damper mecha-
nism.

Avoid Damaging the Glass

Do not abuse the glass in the front door by slamming
the door shut or by striking the glass with a piece of
wood, and never operate your stove if it has damaged
or broken glass. If you need to replace the glass, use
only glass provided by Vermont Castings.

Door Latch
Tab

Rotating
Cam

Washers

Allen Head
Button
Screw

ST618

Fig. 34 The front door seal can be adjusted simply by
adding or removing washers.

Damper

Lock Nut

Set Screw

ST619

Fig. 35 When the damper’s gasket becomes compressed
after prolonged use, the damper should be adjusted to
regain a tight seal.