Electrical wiring (milli-volt) – Monessen Hearth DSSNVMB User Manual

Page 14

Advertising
background image

14

46D0550

46D0550

15

��

���

����

���

���

���

��

���

����

���

���

���

Figure 9 - Installing T-Stat Sensor and Control Knob

T-Stat

Sensor

Wiring

Harnesses

Screws

Knob

INSTALLING THERMOSTAT SENSOR
(OPTION SOLD SEPARATELY)

1. Remove the face plate by removing the six

screws holding the faceplate in place. This will
allow you to pull the faceplate away from the
unit about 3" to 4". See Figure 8.

2. Slip the t-stat sensor behind the faceplate. Attach

the t-stat sensor to the faceplate with 2 screws
provided. Make sure the thermo bulb wire is on
the bottom of the t-stat sensor. See Figure 9.

3. Attach wiring harnesses to back of t-stat sensor.

See Figure 9.

Attach the other ends of the har-

ness to either TP/TH and TH on control valve or
to existing wiring harness with two (2) 0.250"
male spade terminals for remote t-stat operation.
See Figure 7, page 13.

ELECTRICAL WIRING (MILLI-VOLT)

Figure 8 - Removing Face Plate from Stove