4. Remove adhesive backing from plastic clip. Press

clip to bottom of valve. Clip thermo bulb into plastic
clip. See Figure 10.

5. Reattach faceplate.
6. Install knob to shaft of t-stat sensor. See Figure 9,

page 14.

Figure 10 - Clipping Thermo Bulb into

Plastic Clip.

Valve

Thermo

Bulb

Plastic Clip

OPERATION OF THERMOSTAT SENSOR

1. Follow millivolt lighting instructions on lighting plate attached to unit or in homeowner’s manual.
2. With control knob in the “ON” position make sure the ON/OFF switch is in the “OFF” position. See Figure 11.
3. The unit is now being controlled by the thermostat sensor. The sensor will now cycle the burners on and off. You can

adjust how often the unit cycles by turning the control knob on the sensor.

Figure 11 - Control Knob in “ON” Position and ON/OFF Switch in “OFF” Position

Control

Knob

On/Off
Switch

ELECTRICAL WIRING (MILLI-VOLT)

T-Stat Sensor

Optional Blower