PRODUCT SPECIFICATIONS

NATURAL GAS

NOTE: An external regulator is required to reduce supply pressure to a maximum of 10

1

/

2

" w.c. on Natural Gas

systems operating at higher pressure.

MILLIVOLT PRESSURE
Regulator Pressure Setting: 3.5" w.c.
Pilot Regulator: 3.5" w.c.
Gas Inlet Pressure: Max. 10 1/2" w. c. Min. 5" w.c.

IGNITION CONTROLS

Piezo ignitor allows ignition of the pilot without the use of matches.

Milli-Volt control has four (4) positions:

OFF

-

All gas to the burner is shut off at the valve.

IGN

-

Valve position to light/maintain a standing pilot.

ON

-

Valve position to turn burners ON/OFF with remote switch/thermostat.

LOW/HI -

Variable position to control flame height (heat output). Both front and rear burners are in operation to
provide realistic glow and yellow flame.

PILOT/ODS

The gas log heater is fitted with a specially designed safety pilot (ODS assembly) which senses the amount of oxygen avail-
able in the room and shuts the gas log heater off if the oxygen level begins to drop below a satisfactory level. The pilot can
only be relit when adequate fresh air is available.

THERMAL GENERATOR

The millivolt gas log pilot is fitted with a millivolt thermopile generator to provide power for remote activation.

Gas Rate

Model Number

Type

Max. BTU/Hr Min. BTU/Hr

DSSNVMB

Milli-Volt

28,000

18,000

Gas Rate

Model Number

Type

Max. BTU/Hr Min. BTU/Hr

DSSPVMB

Milli-Volt

28,000

20,000

PROPANE / LPG

Note: An external regulator is required to reduce supply pressure to a maximum of 13" w.c.

MILLIVOLT PRESSURE
Regulator Pressure Setting: 10" w.c.
Gas Inlet Pressure: Maximum 13" w.c.
Minimum 11" w.c.