3. To install an MO2 option, insert a 256Kbit RAM (120 nsec, JDEC 32 pin)

in location U9. Be sure that PIN 1 (location on RAM with notch or dot) is
facing down (towards the center of the unit). Note carefully the position of
U9 and the orientation of the RAM in the diagram. Check carefully for

bent or damaged pins. If you are installing sn MO3 option, repeat the

procedure in locations U45 and U46.

Improper orientation of U9, U45, or U46 will destroy the RAM and possibly
cause damage to the unit.

4. Re-connect the backlight cable connector to J10 (see diagram) and replace

the front panel and screws.

5. Connect an IBM KEYBOARD to the KEYBOARD connector. Make sure

that the keyboard is a type which is compatible with an IBM PC XT (not

AT).

6. Re-connect power to the unit. Press the CTRL, ALT and DEL keys on the

IBM KEYBOARD simultaneously. This will reset the unit and normal

operation will begin.

7. Check the installation by pressing HELP on the T-60 followed by F4

(SYS). The memory option should show 64K if you installed an MO2;
128K if you installed an MO3.

8. If the memory option only shows 32K, or the display does not come up

displaying the sign-on message, REMOVE POWER IMMEDIATELY.
Remove the cover and recheck the installation of U9, U45 and U46.