Call plcwrite statement – MITSUBISHI ELECTRIC T-60 User Manual

Page 73

Advertising
background image

CALL PLCWRITE Statement

Purpose:

This command is used to write value(s) to a PLC’s register(s), memory

location(s), or to force one or more output bits in a PLC. Refer to the -PL5
and -SL5 for information on how to use this command with the

Allen-Bradley PLC-5 and SLC-500 processors.

Syntax:

CALL PLCWRITE(id,cmd,start address,# of
registers/bits,expression/variable/array

)

Comments:

id specifies the address of the PLC to which you wish to write. This number
is usually 1 when interfacing to one PLC.

cmd

specifies the write operation you wish to perform. See the table below

for the write operation possibilities:

start address

is the starting address of the bit(s) or register(s) you are

interested in writing. In the case of the Modbus, this does not include a data
type specifier (%, $, !, etc.)

MOD

GE9

TI3

TI5

OM1

PL2

Cmd

Function

Typical Data*

1

Clear Status

Any 5 words

2

Write Input Bit(s)

16 bit words

3

Write Output Bit(s)

16 bit words

4

Write to a Register

1 word per register

5

N/A

N/A

6

N/A

N/A

7

N/A

N/A

8

Write to Analog Output(s)

1 word per output

9

Write to Discrete

Internals/Coils/Relays

16 bit words

10

Write to Holding Relays (bits)

16 bit words

11

Write to Auxilary Relays (bits)

16 bit words

Table 6

Write Operation Options

PLC Interface Commands CALL PLCWRITE Statement

65