inSTaLLaTiOn

1.„ Install„the„replacement„digital„control„box„on„the„pump„

using„the„existing„hardware.„See„Figure„3.

Figure 3. Replacement Digital Box Installation

2.„ Attach„the„relay„kit„to„the„digital„control„box„by„securing„

it„to„the„stud„shown„in„Figure„3,„using„the„appropriate„

hardware„(user„provided).

HATCH

NEW

CONTROL

PANEL

LOCK NUT (4)

SCREW (2)

FLAT

WASHER (8)

HARNESS

RELAY

HEX BOLT (4)

PLUGS

HEX NUT

LOCK

WASHER

FLAT WASHER

CONTROL BOX REAR VIEW

STUD

COnneCTiOnS

Refer„to„Figure„5„for„connections„from„the„relay„to„the„plugs„.
1.„ Connect„#86„purple„12„AWG„wire„from„Relay„K1„to„

terminal„#6„on„Plug„P1„using„a„spade„connector.

2.„ Connect„#85„black„wire„from„Relay„K1„to„starter„ground„

point„using„a„butt„splice.

3.„ Connect„#87„purple„10„AWG„wire„from„Relay„K1„to„

terminal„#4„on„Plug„P1„using„a„butt„splice.

4.„ Cut„wire„from„terminal„#4„on„Plug„P4„flush„to„the„plug.„

Terminal„will„not„be„used.

5.„ Connect„#30„red„wire„from„Relay„K1„to„the„other„end„

of„the„cut„wire„using„a„butt„splice.

6.„ Reconnect„the„4„plugs„to„the„corresponding„receptacles„

on„the„new„control„box.„See„Figure„4„for„location„of„

receptacles.„Receptacle„J5„will„not„be„used.

Figure 4. Control Box Rear Receptacles

7.„ Install„the„fuse„to„the„rear„of„the„new„control„box.
8.„ After„all„connections„are„made,„reconnect„the„battery.„

Turn„the„control„panel„ignition„switch„to„the„ON„position.„

The„control„box„panel„should„light.„You„will„see„and„

hear„the„engine„fuel„solenoid„energize.„

9.„ Perform„control„box„programming„instructions.

NOTICE

Use„extreme„care„when„connecting„the„control„box„rear„

receptacle„plugs„to„make„sure„that„correct„orientation„

is„followed.„

J1

Relay

Fuse

Receptacles

J2

J3

J4

J5

(Not Used)