Control panel components, Figure 8. digital control panel components – Multiquip Control Box Replacement LS60TD User Manual

Page 6

Advertising
background image

LS60TD anD LS600 — COnTROL bOX RepLaCemenT — Rev. #1 (03/23/12) — page 6

COnTROL paneL COmpOnenTS

Figure 8. Digital Control Panel Components

0

5

0

0

7

5

0

1000

12

5

0

1

5

0

0

2

0

0

0

0

5

0

0

7

5

0

1000

12

5

0

1

5

0

0

2

0

0

0

E

M

E

RG

ENCY S

TO

P

ACCUMULATOR

PRESSURE

PUMPING

PRESSURE

1

2

4

5

6

10

9

7

3

8

12

11

13

OFF

ON

IGNITION

REMOTE

CONTROL

FLOW

DIRECTION

VOLUME

LOCAL

FORWARD

AUTOMATIC

JOG

RESET

SET

DECREASE

INCREASE

SCROLL

JOG “A”

CYLINDER STROKE

JOG “B”

REVERSE

CENTER

OFF

REMOTE

START

1.„

emergency Stop button —„Press„emergency„stop„

button„ to„ stop„ pump„ in„ an„ emergency.„Turn„ knob„

counterclockwise„to„disengage„the„stop„button.

2.„

ignition Switch —„Insert„the„ignition„key„here„to„start„

the„engine.„Turn„the„key„clockwise„to„the„ON„position,„

then„continue„turning„clockwise„to„the„START„position„

and„ release.„To„ stop„ the„ engine„ turn„ the„ key„ fully„

counterclockwise„to„the„STOP„position.

3.„

Digital Readout Screen —„Displays„and„monitors„the„

various„functions„of„the„machine.

4.„

Scroll Switch —„ Allows„ the„ operator„ to„ scroll„ the„

various„readout„screens.

5.„

Reset Switch —„ Allows„ the„ operator„ to„ reset„ the„

stroke„counter.

6.„

Remote Cable Connector —„Insert„the„remote„control„

input„cable„into„this„connector.

7.„

Direction Control Switch —„This„2-position„switch„

controls„the„direction„of„flow„for„any„mix„in„the„pump.„„

The„ leftmost„ position„ sets„ the„ pumping„ direction„ to„

forward„and„the„rightmost„position„sets„the„pumping„

direction„to„reverse.

8.„

pumping Control Switch —„This„3-position„switch„

controls„ the„ pumping„ of„ the„ pump.„The„ rightmost„

position„(REMOTE)„is„for„use„with„the„remote„control„

unit,„ the„ leftmost„ position„ (LOCAL)„ is„ for„ normal„

pumping„ operation,„ and„ the„ centermost„ position„

(CENTER„OFF)„prevents„pumping.

9.„

Cylinder Stroke Control Switch —„This„2-position„

switch„ controls„ the„ pumping„ function.„The„ leftmost„

position„ (AUTOMATIC)„ sets„ the„ pump„ to„ automatic„

cycling.„Set„the„switch„to„this„position„for„normal„pump„

operation.

„

The„rightmost„position„(JOG)„changes„the„pump„from„

automatic„to„manual„cycling.„This„allows„the„cylinders„

to„ be„ manually„ cycled„ using„ the„ Manual„ Cylinder„

Jogging„Switch.

10.„

manual Cylinder Jogging Switch —„This„„2-position„

switch„allows„the„operator„to„manually„jog„the„cylinders„

to„assist„in„clearing„material„line„packs„and„is„used„to„

test„pumping„pressure.

„

The„ leftmost„ position„ jogs„ Cylinder„ “A”„ and„ the„

rightmost„position„jogs„Cylinder„“B”.

11.„

Stroke volume Control Switch —„ Increases„ or„

decreases„the„number„of„strokes„per„minute„of„the„

pump„(not„used„on„model„LS60TD).

12.„

accumulator pressure gauge —„ This„ gauge„

monitors„the„internal„pressure„of„the„Accumulator„tank.„

Normal„internal„pressure„should„read„approximately„

1750„PSI„during„pumping.

13.„

main pressure gauge —„This„ gauge„ monitors„

the„ system„ pressure„ while„ pumping„ material.„The„

maximum„pressure„rating„is„4400„PSI„±„50.

Advertising