Chapter 3 Main System Application

[Wave-in Device]:

Allow you to setup GV-System’s audio function. Each channel can be configured separately.

Choose the audio channel in the drop down list and adjust the parameters accordingly to your

specification. The Rec Audio option should be enabled if you wish to activate audio recording

function. The recording is control by the Monitor Sensitivity bar, which is adjustable from level

one to level 10; the higher the value the more sensitive it is to environmental sound and is

more likely to trigger the recording. The Gain Control bar allows you to add boost to the audio

input level.

Auto Reboot Setup

Click [Configure] button, select “Auto Reboot Setup” from the menu, and the following

dialog box will appear. Click on Auto Reboot System to enable this function and the settings

in the dialog box will be unlocked. In [Day Period] you may specify the day interval of each

auto-reboot (range from 1 ~14 days), and in [Reboot Time] specify in what time you want the

system to perform auto reboot.

The [WatchDog Reset if Reboot System Suspend and Fail] option is for avoiding system

lockup during an auto reboot. Enable this function allows the Watchdog function in your

GV-Series video capture card (available in GV-600, GV-650, GV-750, and GV-800 only) to

reset your system if auto reboot fail to restart for more than 5 minutes.

Note:

The WatchDog option will be closed if the option of “Auto run GV-System when window

startup” is not enable during the main application installation.