Network, Network -6 – Moxa Technologies EDS-518A Series User Manual

Page 21

Advertising
background image

EDS-518A Series User’s Manual

Featured Functions

3-6

Speed

Setting

Description

Factory Default

Auto

Allows the port to use the IEEE 802.3u protocol
to negotiate with connected devices. The port and
connected devices will determine the best speed
for that connection.

100M-Full
100M-Half
10M-Full
10M-Half

Choose one of these fixed speed options if the
opposing Ethernet device has trouble
auto-negotiating line speed.

Auto

FDX Flow Ctrl
This setting enables or disables the flow control capability of this port when the “port transmission
speed” setting is in “auto” mode. The final result will be determined by the “auto” process
between EDS-518A and connected devices.

Setting

Description

Factory Default

Enable

Enables flow control for this port when in
auto-negotiate mode.

Disable

Disables flow control for this port when in
auto-negotiate mode.

Disable

MDI/MDIX

Setting

Description

Factory Default

Auto

Allows the port to auto detect the port type of the
opposing Ethernet device and change the port
type accordingly.

MDI

MDIX

Choose the MDI or MDIX option if the opposing
Ethernet device has trouble auto-negotiating port
type.

Auto

Network

The Network configuration allows users to modify the usual TCP/IP network parameters. An
explanation of each configuration item follows.

Advertising