Moxa Technologies EDS-518A Series User Manual

Page 53

Advertising
background image

EDS-518A Series User’s Manual

Featured Functions

3-38

Management VLAN ID

Setting

Description

Factory Default

VLAN ID
ranges from
1 to 4094

Set the management VLAN of this EDS-518A.

1

Port Type

Setting

Description

Factory Default

Access

This port type is used to connect single devices without
tags.

Trunk

Select “Trunk” port type to connect another 802.1Q
VLAN aware switch or another LAN that combines
tagged and/or untagged devices and/or other
switches/hubs.

Access

ATTENTION

For communication redundancy in the VLAN environment, set “Redundant Port,” “Coupling
Port,” and “Coupling Control Port” as “Trunk Port,” since these ports act as the “backbone” to
transmit all packets of different VLANs to different EDS-518A units.

Port PVID

Setting

Description

Factory Default

VID range from 1
to 4094

Set the port default VLAN ID for untagged devices that
connect to the port.

1

Fixed VLAN List (Tagged)

Setting

Description

Factory Default

VID range from 1
to 4094

This field will be active only when selecting the “Trunk”
port type. Set the other VLAN ID for tagged devices that
connect to the “Trunk” port. Use commas to separate
different VIDs.

None

Forbidden VLAN List

Setting

Description

Factory Default

VID range from 1
to 4094

This field will be active only when selecting the “Trunk”
port type. Set the VLAN IDs that will not be supported
by this trunk port. Use commas to separate different
VIDs.

None

To configure EDS-518A’s Port-based VLAN, use the VLAN Setting page to configure the ports.