Trap settings, Private mib information, Using communication redundancy – Moxa Technologies EDS-518A Series User Manual

Page 31: Trap settings -16, Private mib information -16, Using communication redundancy -16

Advertising
background image

EDS-518A Series User’s Manual

Featured Functions

3-16

User Data Encryption Key (for SNMP V1, V2c, V3 and V3 only)

Setting

Description

Factory Default

Enable

8-character data encryption key is the
minimum requirement for data encryption
(maximum of 30 characters)

No

Disable

No data encryption

No

Trap Settings

1

st

Trap Server IP/Name

Setting

Description

Factory Default

IP or Name

Enter the IP address or name of the 1

st

Trap Server used by your network.

None

1

st

Trap Community

Setting

Description

Factory Default

character string

Use a community string match for
authentication (maximum of 30
characters).

public


2nd Trap Server IP/Name

Setting

Description

Factory Default

IP or Name

Enter the IP address or name of the 2

nd

Trap Server used by your network.

None

2nd Trap Community

Setting

Description

Factory Default

character string

Use a community string match for
authentication (maximum of 30
characters).

public

Private MIB information

Switch Object ID

Setting

Description

Factory Default

8691.7.5 EDS-518A’s

enterprise

value Fixed

NOTE: The Switch Object ID cannot be changed.

Using Communication Redundancy

Setting up Communication Redundancy on your network helps protect critical links against failure,
protects against network loops, and keeps network downtime at a minimum.

The Communication Redundancy function allows the user to set up redundant loops in the
network to provide a backup data transmission route in the event that a cable is inadvertently
disconnected or damaged. This is a particularly important feature for industrial applications, since
it could take several minutes to locate the disconnected or severed cable. For example, if MOXA
EDS-518A is used as a key communications component of a production line, several minutes of
downtime could cause a big loss in production and revenue. MOXA EDS-518A supports two
different protocols for this communication redundancy function—Rapid Spanning Tree Protocol
(IEEE-802.1w)
and Turbo Ring.