Preparation for servicing – Philips Magnavox MWC24T5 User Manual

Page 15

Advertising
background image

1-5-1

T2203PFS

PREPARATION FOR SERVICING

How to Enter the Service Mode

Caution 1:

1. Optical sensors system are used for Tape Start

and End Sensor on this equipment. Read this
page carefully and prepare as described on this
page before starting to service; otherwise, the unit
may operate unexpectedly.

Preparing 1:

1. Cover Q1202 (START SENSOR) and Q1201

(END SENSOR) with Insulation Tape or enter the
service mode to activate Sensor Inhibition
automatically.

Note: Avoid playing, rewinding or fast forwarding the

tape to its beginning or end, because both
Tape End Sensors are not active.

How to Enter the Service Mode

1. Turn power on.

2. Use service remote control unit and press [DISC

MENU] button. (See page 1-7-1.)

3. When entering the service mode, one of the

number (1, 2 or 4) will be displayed at corners of
the screen.

4. During the service mode, electrical adjustment

mode can be selected by remote control key.
(Service remote control unit).

Details are as follows.

Caution 2:

1. The deck mechanism assembly is mounted on the

Main CBA directly, and SW1211 (REC-SAFETY
SW) is mounted on the Main CBA. When deck
mechanism assembly is removed from the Main
CBA due to servicing, this switch can not be
operated automatically.

Preparing 2:

1. To eject the tape, press the [STOP/EJECT] button

on the unit (or Remote Control).

2. When you want to record during the Service

mode, press the [Rec] button while depressing
SW1211 (REC-SAFETY SW) on the Main CBA.

Key

Adjustment Mode

PICTURE

Picture adjustment mode: Press the
[PICTURE] button to change from BRT
(Bright), *CNT (Contrast), *COL (Color),
*TNT(Tint), *V-T(V-Tint) and *SHP
(Sharp). Press [CH. o/p] buttons to
display Initial Value.
*Marked items are not necessary to
adjust normally.

0

No need to use.

1

No need to use.

2

H f

0

adjustment mode: See adjustment

instructions page 1-7-2.

3

No need to use.

4

Auto record mode: Perform recording
(15 Sec.) --> Stop --> Rewind (Zero
return) automatically.

5

Head switching position adjustment:
See adjustment instructions page 1-7-6.

6

No need to use.

7

Purity check mode: Shows Red, Green,
Blue or White cyclically on the screen
each time the [7] button is pressed.

8

H. Position adjustment: See adjustment
instructions page 1-7-5.

9

V. Shift/V.Size adjustment: See
adjustment instructions page 1-7-5.

VOL o

No need to use.

VOL p

Cut-off adjustment: See adjustment
instructions page 1-7-3.
White balance adjustment: See
adjustment instructions page 1-7-4.

Key

Adjustment Mode

MAIN CBA

Q1201
(END SENSOR)

SW1211
(REC-SAFETY SW)

Q1202
(START SENSOR)