1-7-4

T2202EA

7. White Balance Adjustment

Purpose: To mix red, green and blue beams correctly
for pure white.

Symptom of Misadjustment: White becomes bluish
or reddish.

Note: Use service remote control unit

1. Operate the unit more than 20 minutes.

2. Face the unit to the east. Degauss the CRT using

a degaussing coil.

3. Input the White Raster (APL 100%).

4. Set the color analyzer to the CHROMA mode and

after zero point calibration, bring the optical
receptor to the center on the tube surface (CRT).

5. Enter the Service mode. Press [VOL p] button on

the service remote control unit and select “C/D”
mode. (Display changes “C/D”, “7F” and Initial
Setting cyclically when [VOL p] button is pressed.)

6. Press [4] button on the service remote control unit

for Red adjustment. Press [5] button on the service
remote control unit for Blue adjustment.

7. In each color mode, press [CH. o / p] buttons to

adjust the values of color.

8. Adjust Red and Blue color so that the temperature

becomes 9200K (x: 286 / y: 294) ±3%.

9. At this time, re-check that horizontal line is white. If

not, re-adjust Cut-off Adjustment until the
horizontal line becomes pure white.

10. Turn off and on again to return to normal mode.

Receive APL 100% white signal and confirm that
Chroma temperatures become 9200K (x: 286 / y:
294) ±3%.

Note: Confirm that Cut Off Adj. is correct after this

adjustment, and attempt Cut Off Adj. if needed.

8. Sub-Brightness Adjustment

Purpose: To get proper brightness.

Symptom of Misadjustment: If Sub-Brightness is
incorrect, proper brightness cannot be obtained by
adjusting the Brightness Control.

Note: SMPTE Setup level --- 7.5 IRE

1. Enter the Service mode. (See page 1-7-1.)

Then input SMPTE signal from RF input.

2. Press [PICTURE] button. (Press [PICTURE]

button then display will change BRT, CNT, COL,
TNT, V-T, and SHP). Select BRT and press [CH. o
/ p] buttons so that the bar is just visible (See
above figure).

Test Point

Adj. Point

Mode

Input

Screen

[CH. o / p]

buttons

RF

White Raster

(APL 100%)

Tape

M. EQ.

Spec.

---

Pattern

Generator,

Color analyzer

See below

Figure

Fig. 3

Color Analyzer

Test Point

Adj. Point

Mode

Input

---

[CH. o / p]

buttons

---

SMPTE

7.5IRE

Tape

M. EQ.

Spec.

---

Pattern

Generator

See below

Figure

Fig. 4

White

Black

This bar
just
visible

Advertising