Sensor cba top view – Philips Magnavox MWC24T5 User Manual

Page 53

Advertising
background image

1-11-15

V-OUT

TP1401

WF5

TO SENSOR CBA
(START-SENSOR)

RF-SW

TP1402

WF1

CTL-AMP-OUT

TP1202

WF3

ENV.

TP1403

WF6

+B ADJ

VR1601

H-OUT

TP1305

WF9

TO SENSOR CBA
(END-SENSOR)

Main CBA Top View < TV/VCR Section >

BT1200F01013

Because a hot chassis ground is present in the power
supply circuit, an isolation transformer must be used.
Also, in order to have the ability to increase the input
slowly,when troubleshooting this type power supply
circuit, a variable isolation transformer is required.

NOTE:
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.

For continued protection against risk of fire,
replace only with same type 4 A, 125V fuse.

CAUTION ! :

ATTENTION : Utiliser un fusible de rechange de m

ê

me type de 4A, 125V.

4A 125V

CAUTION !
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit.
If Main Fuse (F1601) is blown , check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.

BHF300F01011A

BHF300F01011B

Sensor CBA Top View