Philips Magnavox MWC24T5 User Manual

Page 23

Advertising
background image

1-7-3

T2202EA

4. Cut-off Adjustment

Purpose: To adjust the beam current of R, G, B, and
screen voltage.

Symptom of Misadjustment: White color may be
reddish, greenish or bluish.

Notes: Screen Control --- FBT (Sub CBA),

FBT = Fly Back Transformer,
Use the Remote Control Unit.

1. Degauss the CRT and allow the unit to operate for

20 minutes before starting the alignment.

2. Input the Black raster signal from RF input.

3. Enter the Service mode. (See page 1-7-1.)

4. Press the [VOL p] button.

(Press [VOL p] button then display will change
“C/D”, “7F” and Initial Setting.)

5. Choose CUT OFF/DRIVE mode then press [1]

button. This adjustment mode is CUT OFF (R).

6. Increase the screen control so that the horizontal

line just appears on the CRT.

7. Press the [CH. o / p] buttons until the horizontal

line becomes white.

8. Choose CUT OFF/DRIVE mode then press [2]

button. This adjustment mode is CUT OFF (G).
Press [CH. o / p] buttons until the horizontal line
becomes white.

9. Choose CUT OFF/DRIVE mode then press [3]

button. This adjustment mode is CUT OFF (B).
Press [CH. o / p] buttons until the horizontal line
becomes white.

5. H. Size Adjustment

Purpose: To obtain correct size of screen image.

Symptom of Misadjustment: Size of screen image
may not be properly displayed.

Note: VR2531 --- Sub CBA

1. Input monoscope pattern.

2. Adjust VR2531 so that the monoscope pattern is

90+1%/-5% of display size and the circle is round.

6. H. Pincushion Adjustment

Purpose: To obtain straight line on the screen.

Symptom of Misadjustment: Straight line image may
not be properly displayed.

Note: VR2530 --- Sub CBA

1. Input crosshatch pattern.

2. Adjust VR2530 so that the lines of the crosshatch

pattern become straight.

Test Point

Adj. Point

Mode

Input

---

Screen-Control

[CH. o / p]

buttons

RF

Black

Raster

Tape

M. EQ.

Spec.

---

Pattern

Generator

See Reference

Notes below.

Figure

Fig. 2

Pattern Generator

RF Input

Test point

Adj. Point

Mode

Input

---

VR2531

---

Monoscope

Tape

M. EQ.

Spec.

---

Pattern Generator

90+1%/-5%

Test point

Adj. Point

Mode

Input

---

VR2530

---

Crosshatch

Tape

M. EQ.

Spec.

---

Pattern Generator

See below