T2202EA

9. Focus Adjustment

Purpose: Set the optimum Focus.

Symptom of Misadjustment: If Focus Adjustment is
incorrect, blurred images are shown on the display.

Note: Focus VR --- FBT (Sub CBA),

FBT = Fly Back Transformer

1. Operate the unit more than 30 minutes.

2. Face the unit to the East and degauss the CRT

using a degaussing coil.

3. Input the monoscope pattern.

4. Adjust the Focus Control on the FBT to obtain a

clear picture.

10. H. Position Adjustment

Purpose: To obtain correct horizontal position of
screen image.

Symptom of Misadjustment: H. position may not be
properly displayed.

1. Enter the Service mode. (See page 1-7-1.)

Press [8] button on the remote control unit and
select H-P mode.

2. Input monoscope pattern.

3. Press [CH. o / p] buttons on the remote control

unit so that the left and right side of the
monoscope pattern are equal to each other.

11. V. Shift Adjustment

Purpose: To obtain correct vertical position of screen
image.

Symptom of Misadjustment: If V. position is
incorrect, vertical position of image on the screen may
not be properly displayed.

1. Enter the Service mode. (See page 1-7-1.)

Press [9] button on the remote control unit and
select V-P mode. (Press [9] button then display will
change to V-P and V-S).

2. Input monoscope pattern.

3. Press [CH. o / p] buttons on the remote control

unit so that the top and bottom of the monoscope
pattern are equal to each other.

12. V. Size Adjustment

Purpose: To obtain correct vertical height of screen
image.

Symptom of Misadjustment: If V. Size is incorrect,
vertical height of image on the screen may not be
properly displayed.

1. Enter the Service mode. (See page 1-7-1.)

Press [9] button on the remote control unit and
select V-S mode. (Press [9] button then display will
change to V-P and V-S).

2. Input monoscope pattern.

3. Press [CH. o / p] buttons on the remote control

unit so that the monoscope pattern is 90

±5% of

display size and the circle is round.

Test Point

Adj. Point

Mode

Input

---

Focus Control

---

Monoscope

Tape

M. EQ.

Spec.

---

Pattern Generator

See below

Test Point

Adj. Point

Mode

Input

---

[CH. o / p]

buttons

---

Monoscope

Tape

M. EQ.

Spec.

---

Pattern Generator

---

Test Point

Adj. Point

Mode

Input

---

[CH. o / p]

buttons

---

Monoscope

Tape

M. EQ.

Spec.

---

Pattern Generator

---

Test Point

Adj. Point

Mode

Input

---

[CH. o / p]

buttons

---

Monoscope

Tape

M. EQ.

Spec.

---

Pattern Generator

90