Programming Reference

B - 5

MSI

0

Check digits are sent.

1

No check digit is sent.

Example: An MSI bar code 4123, with a single check digit checked, is transmitted as
]M14123

D 2 of 5

0

No options specified at this time. Always transmit 0.

Example: A D 2 of 5 bar code 4123, is transmitted as ]S04123

UPC/EAN

0

Standard packet in full EAN country code format, which is 13 digits for
UPC-A, UPC-E, and EAN-13
(not including supplemental data).

1

Two-digit supplement data only.

2

Five-digit supplement data only.

3

Combined data packet comprising 13 digits from a UPC-A, UPC-E, or
EAN-13 symbol and 2 or 5 digits from a supplemental symbol.

4

EAN-8 data packet.

Example: A UPC-A bar code 012345678905 is transmitted as ]E00012345678905

Bookland EAN

0

No options specified at this time. Always transmit 0.

Example: A Bookland EAN bar code 123456789X is transmitted as ]X0123456789X

Code 11

0

Single check digit

1

Two check digits

3

Check characters validated but not transmitted.

GS1 DataBar
Family

No option specified at this time. Always transmit 0. GS1 DataBar-14
and GS1 DataBar Limited transmit with an Application Identifier “01”.

Note: In GS1-128 emulation mode, GS1 DataBar is transmitted using
Code 128 rules (i.e., ]C1).

Example: A GS1 DataBar-14 bar code 100123456788902 is transmitted as
]e001100123456788902.

Table B-3

Modifier Characters (Continued)

Code Type

Option Value

Option