IV. THERMOCOUPLE INSTALLATION

1. Install the thermocouple sensing bulb into the correct

hole in the rear of the oven, as shown in Figure 2-3.

2. Thread the thermocouple lead through the grommet

and into the machinery compartment.

3. Remove the right-side access panel of the machinery

compartment.

4. Thread the thermocouple lead through the side of the

machinery compartment as shown in Figure 2-4, and

into the electrical box (at the right-front of the machin-

ery compartment).

5. Connect the thermocouple leads to the temperature

controller as shown in Figure 2-5.

6. Repeat Steps 1-5 for each of the other oven sections in

the installation.

8=White=Positive

7=Red=Negative

R=No Connection

Ground=Shielded cable

Figure 2-3

Thermocouple Installation Locations

Figure 2-4

Placing the Thermocouple Leads

Figure 2-5

Thermocouple Lead

Connections

Use for conveyor

Use for conveyor

Thread lead into

machinery

compartment here

Thread lead into

machinery

compartment here