2-12

SECTION 2

INSTALLATION
VI. ELECTRICAL SUPPLY

WARNING

Authorized supplier personnel normally accomplish the

connections for the ventilation system, electric supply,

and gas supply, as arranged by the customer. Following

these connections, the factory-authorized installer can

perform the initial startup of the oven.
NOTE: The electric supply installation must satisfy the

requirements of the appropriate statutory authority, such

as the National Electrical Code (NEC), ANSI/NFPA70,

(U.S.A.); the Canadian Electrical Code, CSA C22.2; the

Australian Code AG601; or other applicable regulations.
NOTE: The electric supply connection must meet all

national and local electrical code requirements.
Check the oven data plate before making any electric

supply connections. Electric supply connections must

agree with data on the oven data plate. See Figure 2-26.
A fused disconnect switch or a main circuit breaker

(customer furnished) MUST be installed in the electric

supply line for each oven. It is recommended that this

switch/circuit breaker have lockout/tagout capability.
The supply conductors must be of the size (#14 AWG,

copper) recommended. Refer to the wiring diagrams in

Section 5 of this manual.
All gas oven electric supply connections are made via the

electrical junction box on the rear of the oven, shown in

Figure 2-27. The power lines then connect to the oven

circuits through the Machinery Compartment Access

Panel Safety Switch. This switch interrupts electric power

to the oven when the Machinery Compartment Access

Panel is opened.

CAUTION

Before connecting incoming power to the oven, measure

the voltage of each input leg to neutral. The expected

voltage is approximately 120V. ANY voltage reading

exceeding 130V indicates that the supply has a “high” leg.

CONNECTING A “HIGH” LEG TO THE OVEN VOIDS ALL

OVEN WARRANTIES. Connecting a “high” leg to the

black lead of the oven can severely damage the oven’s

electrical and electronic components.

CAUTION

DO NOT CONNECT BLACK WIRE TO

HIGH LEG. VOLTAGE OF THE BLACK

AND WHITE WIRES MUST BE NO

HIGHER THAN 130 VAC

Figure 2-26

Oven Data Plate

FOR DOMESTIC OVENS (WITHOUT EXTERNAL

TRANSFORMERS):

In the junction box on the rear of the oven, connect one

208 - 240V supply line to the black wire and the other

208 - 240V supply line to the red wire. Connect the

electric supply ground wire to the oven ground screw

located in the junction box. If necessary, have the

electrician supply the ground wire. Do NOT use the

wiring conduit or other piping for ground connections!

FOR EXPORT OVENS (WITH EXTERNAL

TRANSFORMERS):

First, position the transformer on the LEFT REAR wall

of the oven (as space permits), and fasten it in place

using the supplied mounting hardware.
Then, refer to the appropriate wiring diagram in Section

5 of this manual to determine the correct transformer

connections for the supply lines. Connect the electric

supply ground wire to the oven ground screw located

in the junction box. If necessary, have the electrician

supply the ground wire. Do NOT use the wiring conduit

or other piping for ground connections!